: Installers must remove the Electrostatic Discharge (ESD) tape from the back connectors before use, as leaving it in place can cause the microprocessor to short out. Post-Installation and Configuration

The Kt 70 does not directly plug into the PAS sensor – the PAS sensor connects to the controller. The controller then sends data to the display. Ensure your PAS sensor (12 or 8 magnets) is properly installed on the bottom bracket.

| Terminal | Output Type | Connection | |----------|-------------|-------------| | 8 & 9 | Relay (SSR/Contactor) | 8 = NO, 9 = COM | | 8 & 10 | 4-20mA current | 8 (+), 10 (–) | | 8 & 11 | 0-10V voltage | 8 (+), 11 (–) |