Christophe Basso Designing Control Loops For Linear And Switching Power Supplies Pdf Access
This is a major focus. Basso explains the inner current loop, slope compensation, and how to model the current-mode power stage without falling into common pitfalls (e.g., the incorrect assumption of a first-order system).
The optimization process begins with the measurement of the control loop gain and phase response. This is typically done using a network analyzer or a frequency response analyzer. The gain and phase response can be used to identify any potential stability issues and optimize the control loop for maximum performance. This is a major focus